With the controller installed, I can configure the purifier and check its readings from a browser. The dashboard runs on the ESP32, so it works on my local network without a cloud account.
This guide walks through the initial setup, then covers everyday use, Home Assistant, backups and updates. Follow sections 1–5 for a new installation; section 4 is optional if you do not want maintenance reminders yet. If your purifier is already configured, use the contents to jump to the task you need.
Before you start
The instructions and screenshots cover Youth V2.3 with firmware 0.16.9. They assume the board is assembled, flashed and electrically checked. For compatibility checks, parts, wiring and the firmware download, start with the board assembly and Windows flashing guide. The firmware is specific to this board.
Have these ready:
- A phone or computer with a browser and access to the controller's local network.
- Your wiring notes and the specifications of the sensors, pump and optional UV module you installed.
- Your own calibration values and measured protection limits. Screenshot values describe my installation.
For a newly assembled board: keep the pump, valves and UV disconnected during the initial electrical checks. In Diagnostics → Maintenance controls → Diagnostic snapshots & reports, use Read diagnostics to inspect U6 pump-monitor communication and supply readings. Check U7 feedback too if you fitted UV. Finish the physical wiring and electrical checks before connecting loads or enabling operation. The separate Current monitors & I2C addresses tools perform service actions; they are not needed just to read a snapshot.
Some buttons in my screenshots are disabled because automatic operation was still enabled when I captured them. In the steps below, you will stop operation before changing settings.
Overview on the running controller, with automatic operation armed and the machine in standby.
1. Connect to the dashboard
Open the local interface
Choose the route that matches your controller.
Already connected to your home Wi-Fi:
- Connect your phone or computer to the same local network.
- Find the controller's IP address in your router's device list or its startup log.
- Enter
http://<device-ip>/in the browser, replacing<device-ip>with that address. The dashboard opens under/ui/.
First connection through the setup hotspot:
- Obtain the generated hotspot password from the controller's startup log, using the serial-console instructions below.
- Join the controller's
Water-XXXXXXWi-Fi network. Stay connected if your phone says it has no internet access. - Open
http://192.168.4.1in the browser.
Getting the hotspot password during bench setup
An already-networked purifier can skip this procedure. For an unconfigured board, keep external loads disconnected and use the board's verified UART0 connection:
- With board power off, connect a 3.3 V USB-to-UART adapter's RX to UART0 TX (GPIO43) and connect GND to GND. Leave the adapter's power pin disconnected; this is a receive-only connection.
- Open a serial terminal at 115200 baud, 8 data bits, no parity, 1 stop bit.
- Start the board using its verified power arrangement. Read
SETUP: SSID=Water-XXXXXXandSETUP password=…in the startup log.
Keep that password private. Do not combine the board's USB supply and 24 V supply unless you have checked that power arrangement.
Check before continuing: the dashboard should show a current connection and the expected firmware version. Keep its HTTP interface on a trusted local network, without internet port forwarding. If an update is awaiting confirmation, go straight to firmware confirmation; its three-minute deadline still applies.
Understand the pages and the save workflow
Most setup work happens in Device settings. The other pages provide readings, network configuration and troubleshooting tools.
| Page | What you use it for |
|---|---|
| Overview | Check operation, alerts and maintenance reminders |
| Water circuit | See readings alongside the configured water path |
| Quality & flow | Review current readings, water totals and history |
| Filter care | Check cartridge reminders and service records |
| Device settings | Configure the installation, sensors, reminders and protection; manage backups and updates |
| Network | Connect Wi-Fi and Home Assistant through MQTT |
| Diagnostics | Inspect faults, device health, service tools and the clock |
| Activity log | Read saved events and recent safety events |
Use this pattern whenever you change configuration:
- Select Stop operation and wait until the device reports that automatic operation is stopped.
- Make your changes in the relevant panel.
- Select that panel's Save button.
- Check the result and confirm that the values returned by the device match your changes.
Waiting for demand is still enabled operation: the pump may be off while the controller is ready to start. Explicitly stop it before editing settings.
If the controller restarts, another page changes a setting, or a save response is lost, select Reload to check what is currently saved. Reload can discard unsaved edits. Saving settings leaves production stopped; you will use Enable operation separately in section 5.
2. Verify the installation
Complete the input checks first, then confirm the water path. Saving new input settings invalidates the previous water-path confirmation.
Verify pressure switches and the leak input
Open Device settings → Purifier setup → Step 1 · Verify the switches.
Purifier setup, Step 1. Verify the physical inputs; do not copy the example LOW selections.
| Input | What its active state means |
|---|---|
| AD1 | Inlet supply pressure is available |
| AD2 | Production or pressure-tank refilling is requested |
| AD3 | The configured leak probe detects wet conditions |
- Check AD1 and AD2 against the actual switches in both relevant physical conditions. If measuring contact continuity, disconnect the contact from powered circuitry and measure it unpowered.
- Set each switch's Active electrical level from those observations. LOW and HIGH describe electrical levels; do not infer them from a “normally closed” label alone.
- Review Confirm a level after, the debounce time in milliseconds. Mark Physically verified only after checking the corresponding input.
- Test the specified AD3 resistive leak probe in dry, wet and restored-dry conditions, away from exposed electronics. Its wet state is LOW and its confirmation timing is fixed. AD4 is reserved.
- Select Save input verification and check the saved result.
Next: reload Step 2 and confirm the water path again. This is required even if the old installation settings look unchanged.
Confirm the water path and cycle timing
Open Step 2 · Confirm the water path.
Purifier setup, Step 2. Timing values shown here belong to this installation.
- Select Direct flow for a matching tankless system, or Pressure tank for an independently checked tank installation. Each mode keeps its own timing profile.
- Review the cycle settings using the units below.
- Enable only the Installed water-quality probes you fitted. CH1/NTC1 measure source water; CH2/NTC2 measure product water. For a tank system, the specified product measurement location is before storage.
- After checking the physical installation, select Installation verified, then Save installation.
- Check that the intended mode and values are saved. Operation should still be stopped.
| Setting | Unit | What it controls |
|---|---|---|
| Open valves before starting the pump | ms | Delay between opening valves and starting the pump |
| Minimum time between pump starts | ms | Minimum off interval before another start |
| Maximum continuous cycle | seconds | Cycle limit, including preparation and timed rinses |
| Rinse before production | seconds | Rinse with the pump and both valves operating; zero skips it |
| Rinse after production | seconds | Inlet-pressure rinse with the pump off; zero skips it |
| Minimum interval between cycle rinses | seconds | Pressure-tank mode's interval for skipping repeated cycle rinses |
Selecting a mode does not alter the plumbing or switch polarity. In this installation, normal production leaves the flush output unpowered while concentrate drains through the restricted path. Reaching the pressure stop condition still ends production, regardless of the cycle time remaining.
3. Configure the hardware you installed
Enable fitted sensors, enter their initial calibration values, then review the protection settings. Skip the UV section if you have no compatible UV hardware.
Configure sensors and flow calibration
Enable the installed channels
- Open Device settings → Sensors.
- In Installed sensors, enable the fitted flow meters and source/product water-quality and temperature channels.
- Select Save changes and check that those selections were saved.
The flow-calibration panel has a separate save button.
Flow calibration uses pulses per litre. The displayed 2280 is an example, not a universal coefficient.
Enter the initial flow coefficients
- Under Flow-meter calibration, check Meter installed for each fitted meter. FLOW1 is product water; FLOW2 is waste water.
- Enter each meter's Calibration coefficient in pulses/L, using the specification for its identified model. The two channels can have different coefficients.
- Select Save flow calibration. Allow a new five-second measurement window before reviewing the reading.
The displayed 2280 belongs to my setup. Use your meter's value as the starting point.
Refine calibration after a supervised production test
Do this after the installation is verified and can run under the conditions in section 5:
Note the meter's cumulative volume before collection.
Collect and measure a known volume at stable flow, within the meter's useful range. Note the cumulative volume afterward.
Stop automatic operation before changing the coefficient.
Calculate the corrected coefficient using the same collection interval:
displayed litres = total after collection − total before collectionnew coefficient = old coefficient × displayed litres ÷ measured litresSave the new value with Save flow calibration and allow a fresh five-second measurement window.
Review and save any enabled flow-protection settings again, because they depend on the calibration configuration.
If you have a direct pulse count, the coefficient is counted pulses ÷ collected litres. Saving a coefficient preserves accumulated totals and does not recalculate earlier water usage.
About water-quality readings: the quality module supplies conductivity and temperature; TDS uses a conductivity factor of 0.5. This page does not calibrate that module. Check the connection when a reading is missing; zero alone does not establish that a probe is working. TDS is only one measurement, not a complete drinking-water assessment. Continuous pressure sensing and extra valves SV3–SV5 are not configurable in this firmware.
Set additional protection limits only when measured
These settings add electrical, flow and runtime checks to the basic pressure-switch and leak behavior. Choose limits from measurements of your installation.
Additional protection settings. The zero values shown disable those individual optional limits; they are not a recommended protection profile.
- Open Device settings → Protection.
- Use Water path to select the profile you want to edit. This selector does not change the machine's operating mode.
- Enter the measured limits and their confirmation delays, checking the units below.
- Select Limits verified for this machine, then Save protection profile.
- Confirm that the intended profile and values were saved.
| Group | Units and behavior |
|---|---|
| Pump & power supply | Current in A, voltage in V; violations can prevent or stop operation |
| Water flow | Rates in L/min, stopped-waste allowance in L; needs suitable enabled, calibrated meters |
| Starts & runtime | Starts and pump minutes in a rolling hour; these counters reset on reboot |
| Water-quality warnings | Product TDS in ppm, rejection in %; these warn without stopping the pump |
| How long to wait before acting | Delays in seconds for startup, persistent violations and stopped observations |
A zero trigger limit disables that optional check; timing fields have their own positive requirements. For rejection warnings, use valid, calibrated probe data, a Minimum feed TDS for rejection calculation above zero, and a rejection threshold below 100%.
The form's numeric range is not the board's electrical rating. If a protection fault appears, investigate the condition and sensor readings before changing a limit to silence it.
Configure the optional UV module
This firmware's UV policy supports a matching instant-on UVC LED module after the final filter in a direct-flow system. It does not support pressure-tank operation. Leave UV disabled when this hardware is absent.
Optional UV settings use mA. Choose limits for the actual module; do not copy the captured values.
- In Device settings → Sensors, find UV lamp below the other sensors.
- Verify the module type, wiring, supply and enclosed, water-filled chamber.
- Select Enable the installed UV lamp and Installation verified.
- Set the current limits in mA, plus any advanced grace periods and confirmation delays in milliseconds.
- Select Save changes and check the saved values.
For enabled current-threshold checks, use this relationship:
0 < maximum current when off < minimum current when on < maximum current when on
The highest accepted input is 1500 mA; that is a software limit, not a board-capacity claim. Version 0.16.9 also accepts all three thresholds at zero, which disables only these current-threshold checks. Other feedback and operating checks still apply.
Result: the module participates in normal operation when conditions permit. Saving this setting does not turn it on immediately. Electrical readings alone cannot establish UV intensity or disinfection performance.
Set a lamp-service reminder, if needed
- Under Lamp care → Reminder plan, select Enable lamp service reminders.
- Enter the manufacturer's service interval in commanded-on hours, calendar days, or both. Zero disables that particular age limit; an enabled reminder needs at least one nonzero limit.
- Select Save reminder plan.
- Check the controller clock as described in section 4. Use Register first new lamp or Record lamp replacement only after the corresponding physical work.
The reminder tracks service age. It neither enables the UV output nor stops production when due.
4. Set up maintenance reminders
Maintenance reminders are optional. To use them, first describe the installed cartridges, then check the clock before recording a new cartridge or replacement.
Set up filter reminders and the controller clock
Save the cartridge list
One saved cartridge record. Editing its reminder plan is different from recording a physical replacement.
- Open Device settings → Filters.
- Choose Add filter. If the list is empty, Use five-stage layout is another starting point when it matches your machine. You can keep up to eight records.
- Give each cartridge a name, type and water-path position. Arrange them to match the installation.
- Enable Service reminder where needed. Set Replace after (days), Production time (hours), or both, using the cartridge maker's guidance for your application.
- With operation stopped, select Save filter list and check the result.
Zero disables an individual reminder limit; at least one must be nonzero for an enabled reminder. Saving the list records the configuration, not a filter replacement.
Check the controller clock
- Open Diagnostics → Maintenance controls → Controller clock.
- Check the displayed time and its source.
- If network time is unavailable, check your computer's clock, then select Synchronize from this computer and confirm.
This updates the device clock. Do it before recording installation dates: synchronizing later cannot recover an installation date that was never recorded.
Record actual installation or replacement
- After fitting a genuinely new cartridge, select Record new cartridge for its record. For a previously registered cartridge you have just replaced, use Record replacement.
- Check the cartridge named in the dialog and confirm.
- Open Filter care to review its service record and reminder.
If a cartridge is already in use, do not record it as newly installed. Remaining-life percentages estimate service age from your configured time limits and recorded use; they do not measure filtration capacity. Per-cartridge litre limits are unavailable. Removing a cartridge record hides it while preserving its history.
5. Enable operation and check the results
At this point, the physical installation, input checks and water-path confirmation should be complete. Review any enabled protection profiles and optional UV settings before starting.
Use the daily pages without changing configuration
- Select Enable operation and confirm. The controller is now ready to respond to demand; the pump may start when its conditions allow.
- Check Overview for the resulting state: waiting, producing, stopped or faulted.
- Open Water circuit to check the readings and commanded pump/valve states.
- During supervised production, inspect the actual machine alongside the dashboard. Use stable production readings when assessing RO rejection.
The water-path animation follows controller commands. It does not measure the physical position of a valve.
Recorded quality and flow history. The current readings were captured in standby, not during a membrane-performance test.
Read the history correctly
In Quality & flow, current rates, accumulated litres and history describe different things. The screenshots show standby readings, which are unsuitable for assessing membrane performance.
| View | What firmware 0.16.9 displays |
|---|---|
| Current readings | Available sensor measurements; check the operating state alongside them |
| Cumulative totals | Accumulated litres, not automatically today's consumption |
| 24 h | Five-minute records from the current statistical day's midnight to now, rather than a rolling 24 hours |
| 7 days / 30 days | Daily summaries; gaps and partial records can remain |
The statistics time zone determines the local day used for new records. Closing the browser leaves the controller running locally. A disconnected or stale page cannot confirm its current state.
Stop operation or respond to an alert
- Stop operation sends a stop request immediately. Wait for the device's response; use physical isolation when needed, rather than relying on a software stop as an emergency disconnect.
- For a fault, inspect Current alerts and Last recorded fault in Diagnostics. Resolve the cause before selecting Clear fault. Clearing the fault leaves automatic operation stopped.
- Mute alarm silences the sound while leaving the fault and protection in place.
Adjust rinsing, sound and the screen
- Stop automatic operation and open Device settings → Rinsing & sound.
- Set Manual rinse duration and Idle rinse duration in seconds. Set Rinse after idle in hours; zero disables scheduled idle rinsing.
- Adjust Audible alerts and On-device screen brightness if needed, then save the panel and check the result.
Saving preferences does not start a rinse. To rinse manually, keep automatic operation stopped, check that the water path is ready, then select Manual rinse and confirm. This requests an inlet-pressure rinse with the pump commanded off.
Brightness controls the fitted display. Backlight standby also requires compatible screen-side software; updating the ESP32 alone does not install it.
Optional: Wi-Fi and Home Assistant
You can use the dashboard without Home Assistant. If you are still connected through the setup hotspot, use the Wi-Fi steps here to join your home router.
Connect Wi-Fi and Home Assistant
Join your home Wi-Fi
- Stop automatic operation and open Network → Connect to your router.
- Enter the exact Network name and Wi-Fi password for a 2.4 GHz WPA2/WPA3 personal network.
- Select Connect & save. Allow up to 60 seconds; the dashboard may disconnect during the attempt.
- Find the controller's new address, reconnect and check Router connection: Connected.
Credentials are saved after a successful connection. A failed attempt restores the previous settings. Open setup hotspot is a separate action useful when changing routers; this form does not display the existing hotspot password.
Connect Home Assistant through MQTT
First set up a local MQTT broker and connect Home Assistant's MQTT integration to it. The official Home Assistant MQTT guide covers that prerequisite. Create login credentials for the controller on the broker.
MQTT connection settings. Use your own broker address and credentials.
With operation stopped, open Network → Home Assistant & MQTT:
- Check Enable MQTT & discovery.
- Enter Broker address as a reachable hostname or IPv4 address, without a scheme, path or port.
- Set Broker port, usually
1883, and enter Username. Keep the discovery prefix athomeassistant. - Under Saved password, select Set new password and fill New password.
- Select Save MQTT settings, then check Broker connection: Connected.
- In Home Assistant's MQTT integration, find
Water <id>and check its entities. Normal publication is about every ten seconds.
Result: Home Assistant receives the controller's data. This integration is read-only; it cannot start the pump or open valves. Confirm the entities in HA even if the controller shows Last published data.
Use the same broker as HA. localhost points to the controller itself, and HA's web port 8123 is not the MQTT port. This firmware uses unencrypted TCP, so keep it on a trusted LAN. My screenshot has empty account fields for a local test broker; configure your own credentials. When changing broker identity, explicitly replace or clear the saved password.
Add the Water Purifier dashboard cards
Once the MQTT entities are updating in HA, you can add my Water Purifier Card. The same file provides a full water-circuit card, a small status card, and a medium water-quality/history card. It displays the entities already in Home Assistant; it does not connect directly to the MQTT broker or replace the board's firmware.
The instructions below use the repository's 0.4.0 source candidate and its manual installation route. There is no tagged release yet. The repository includes a HACS custom-repository route, but HACS installation/update is still being validated and the project is not in its default catalog.
- Download the JavaScript file. Open
water-purifier-card.json GitHub and use Download raw file. Save the.jsfile itself, not a GitHub web page renamed to.js. - Copy it to Home Assistant. Put the file at
www/water-purifier-card.jsinside HA's configuration directory, commonly/config/www/water-purifier-card.js. If you just createdwww, restart HA once. HA serves this folder under/local/; see HA's file-hosting documentation. - Register one resource. In Settings → Dashboards → ⋮ → Resources, add
/local/water-purifier-card.js?v=0.4.0with resource type JavaScript module, following HA's resource instructions. All three cards share this entry; do not register three copies. If your installation manages dashboard resources in YAML, use the repository's YAML resource instructions instead. - Reload and add a card. Refresh the browser, edit your dashboard, and choose the full, status or history Water Purifier card from the card picker. Select your WATER device in the visual editor. Start with the small status card if you only want to check state, product TDS and flow.
- Check entity matching. Compare the displayed readings with the device's entity states in HA. The editor also lets you map fields explicitly. Use the entity with the correct meaning. Choose Hide for fields belonging to absent accessories, or set the corresponding roles to
nullunderentitiesin YAML; leaving a role unspecified allows automatic matching. A missing firmware entity cannot be created by selecting a card layout. - Save and verify. Save the card, then check it on the normal dashboard. Clicking a mapped reading opens HA's entity details. An optional controller-dashboard link opens the board's web interface in your browser; enter an address that your browser can reach.
If you prefer YAML, this is a starting point for the small card:
type: custom:water-purifier-status-card
title: Kitchen water
language: auto
device_id: REPLACE_WITH_HA_DEVICE_REGISTRY_ID
Replace the placeholder with the device's Home Assistant registry ID, or use the visual device selector instead. The firmware's water_<MAC> identifier is not that registry ID. For the other layouts, use custom:water-purifier-card or custom:water-purifier-history-card; the repository provides full, status and history configurations with explicit entity mappings.
To update the card later: replace the JavaScript file, change the version query on its existing resource entry, and reload the browser. Keep just one resource entry for the file. This frontend update does not require a firmware flash when the entities it needs already exist.
Read the card and troubleshoot missing data
- History is stored by HA. The full and medium cards use the mapped product-TDS entity's Recorder history, not the ESP32's local history. A working live value can coexist with an empty graph if HA has no records yet or excludes that entity. The small card does not request history.
- Totals are cumulative. Product total, waste total, production time and starts are device counters. Changing the graph's time window does not turn those totals into daily usage.
- Match your filters. Set names and diagram associations to match the installed filters. The firmware's reminder slots do not supply filter names or remaining-life percentages. A disabled reminder does not mean a physical filter is absent.
- The cards do not issue device commands. State animations are visualizations of reported operation, not measurements of water movement or valve position. Use the controller's own web interface for operation settings.
| What you see | What to check |
|---|---|
| “Custom element doesn't exist” | Resource URL, JavaScript module type, whether the downloaded file is real JavaScript, and a full browser reload. |
| No WATER device or readings | Finish MQTT discovery first; check that the controller and HA use the same broker. |
| Device exists, but a field is empty | Correct device selection, enabled HA entities and explicit field mapping. Optional fields depend on what your firmware publishes. |
| Live TDS works, but no trend | HA Recorder inclusion and stored history for the mapped product-TDS entity. |
| An update still shows the old card | Replace the file at the existing path, update its resource version query and reload. Avoid duplicate /local/ and /hacsfiles/ copies. |
Backups, updates and troubleshooting
These are maintenance tasks to return to when needed. They are not additional steps you must complete before normal use.
Export configuration and understand restoration
Name the controller and choose the statistics day
- Open Device settings → Data & backup with operation stopped.
- Edit Device name and Statistics time zone as needed.
- Select Save name & time zone and check the saved values.
The time zone is a fixed UTC offset. It does not follow daylight-saving changes automatically; older records retain their original day assignment.
Device name, fixed statistics time-zone offset, and configuration export options.
Export a backup
- Select Export configuration for a backup without passwords.
- If you need saved Wi-Fi and MQTT passwords in the file, choose Export with passwords and confirm instead. Store that file privately: the passwords are readable.
Neither export transfers device access credentials or provides a complete measurement-history archive.
Restore a backup
Before restoring, keep a way to find or reconnect to the controller. A password-free backup can reuse the current Wi-Fi password only for the same SSID. Reusing an MQTT password requires the same broker address, port and username. Otherwise Wi-Fi returns to unconfigured/setup access or MQTT stays disabled, and you will need to enter credentials again.
- Stop operation, select Choose a file to restore, and load a compatible configuration file.
- Review it, then select Restore & restart to replace the configuration and restart the controller.
- Reconnect and recheck the physical installation.
- Repeat Step 1 → Save input verification, then Step 2 → Save installation. Review and save each enabled protection profile.
- If UV is fitted, verify and re-enable it separately. Check all saved settings before considering Enable operation.
Restoration clears input, installation and protection confirmations, and restores UV disabled and unconfirmed. Lifetime water totals, filter baselines and service history stay on this controller. UV usage and service history also stay; a compatible backup transfers its reminder plan, not another lamp's history.
Older four-slot exports use Diagnostics → Legacy configuration migration, rather than this full-restore form.
Update firmware and confirm the new version
Back up the settings, stop automatic operation, and wait for any service tasks or pending work to finish. Use a matching signed application .bin for this board and release. A merged factory image, bootloader, partition table or screen firmware does not belong in this form; OTA leaves the partition table unchanged.
The device reports 0.16.9 and youth-v2.3. This form takes a matching signed application image, not a factory image.
- Open Device settings → Firmware → Firmware & recovery.
- Expand Install a signed application and select the matching application file.
- Select Upload & restart, review the confirmation and keep power connected. Wait for the device to verify the image; reaching 100% in the browser is only the upload stage.
- Reconnect after restart. Check the reported version and device state.
- Once startup checks permit it, select Keep this version and confirm within three minutes of startup.
Confirmation requires at least ten seconds of firmware uptime and the required healthy state. Leave water operation stopped during these checks; there is no requirement to produce water for ten seconds.
Without confirmation, the controller attempts rollback. Check its reported outcome rather than assuming rollback succeeded. If an upload times out or its response is lost, inspect the running version and update status before trying again.
Use diagnostics to investigate a specific problem
Start with the reported symptom, rather than running every available service tool.
A historical fault snapshot retained after the event. It is not an active alarm or a recommendation for UV thresholds.
- Open Diagnostics. Compare current alerts and sensor readings with Last recorded fault. A historical snapshot can remain after the immediate condition has cleared.
- Use Read diagnostics to retrieve an observation snapshot.
- If you need help investigating it, use Export support report. Review device, network and configuration details before sharing the file.
Read logs when a snapshot is not enough
- In the remote console, Start viewing reads application log fragments. Clear view clears the browser display, not the device's saved events. Download useful logs before closing the tab; this is not a complete serial or crash dump.
- In Activity log, select Refresh archive and Older events to read saved history. Export loaded events includes only what is loaded. Recent safety events are separate, and pending records may not yet be saved.
Service tools change hardware state. Indicator, buzzer and screen checks command those components. Test U3 EEPROM writes a scratch area and attempts restoration; monitor checks can reset and restore registers. Pump/valve pulse tests require a stopped, verified installation and physical BOOT authorization for one pulse. Use these only for a specific troubleshooting task.
Common questions
Why is Save disabled while the pump is off?
The controller may still be armed and waiting for demand. Select Stop operation, wait for the current state, and check for a pending update, service task or settings conflict. Some buttons also require a changed field.
Why can't I enable operation after saving the switches?
Saving the inputs invalidates the previous installation confirmation. Reload Step 2, recheck the water path and save installation again. Keep the switch polarity based on your physical measurements.
Why is a sensor unknown or a filter percentage missing?
Check the installed channel and diagnostics for sensor problems. Filter reminders need a saved plan and a genuine service baseline; calendar reminders also need a valid installation date.
Will closing the browser stop the purifier?
No. Use Stop operation and wait for the controller's response. Closing the page only ends your view of a controller that continues running locally.
Keep your wiring notes and an exported configuration alongside this guide. The RO controller project page collects the build history and related articles.












Comments
Questions about this build? Share what you tried and what happened.
Loading the discussion…
Comments could not load. You can keep reading and try again.
New comments are closed for this article. Existing discussions are still available to read.
Your submitted comments
Shown only to you. Not part of the public discussion yet.
Discussion
No comments yet. Questions and build notes are welcome.
Replying to
Replying to