The Youth Edition V2.3 board after the failure, with the ESP32 module removed for inspection.
My DIY reverse-osmosis controller reached a few working milestones: the firmware booted, the ESP32 connected to Wi-Fi, and one voltage-monitoring channel reported about 24 V. Then, while reworking another part of the board, I installed a chip the wrong way round and damaged the ESP32.
The markings on the chip were difficult to read, and I misidentified its orientation. I later confirmed that I had installed U7 backwards during rework. The ESP32 is now off the board, and I still need to check the rest of the board for damage.
In my first post, I explained why I wanted a smarter controller for my purifier. This is what happened when I started assembling and debugging it.
Getting the board running
I’m assembling the Youth Edition V2.3 of yuunt’s open-source water purifier controller design, starting with a bare PCB. The hardware design comes from that project; my work here is assembly, firmware development, and testing.
I began with the 24 V input and power-conversion circuitry. After soldering that section, I measured the 5 V and 3.3 V rails. Both were at their expected voltages, so I continued with the USB and programming circuitry and the ESP32-S3 module.
USB was the first obstacle. The board received power, but my computer initially failed to recognize it with either an A-to-C or a C-to-C cable. After checking and working on the connector, I finally got a serial port and could read the ESP32-S3 startup messages. I did not pin down which connection had caused the original problem.
Flashing also took a few attempts, including a synchronization error, but eventually the firmware booted and the board connected to Wi-Fi.
I saved a screenshot of that network check. The terminal shows replies to ping on the local network. The browser still says “Not connected to device” because I had not entered the web interface’s admin token at that point. Those were two separate stages of getting access to the device.
One voltage reading working, one monitor missing
With the controller running, I continued assembling the pump, valve, UVC, and monitoring circuits. The TDS chip had not arrived, so that part remained unpopulated.
These were no-load diagnostic checks. The firmware kept the pump, valve, and UVC outputs locked off; I had not begun testing the board in the purifier.
The two INA226 monitoring chips then gave me different problems. U6, on the pump-monitoring side, responded at address 0x40, but its voltage reading stayed at zero. U7, on the UVC-monitoring side, did not respond at its expected address, 0x41.
For U6, I checked the relevant supply and sensing points and used firmware diagnostics to inspect the chip’s responses. After further work and another check, the voltage reading came back.
Before the later failure: U6 reported 23.981 V, while U7 was not detected. The displayed current was uncalibrated; no load test had been completed.
That reading gave me a concrete result beyond simply getting the board online. One monitoring channel was now reporting the supply voltage. U7 remained the problem to investigate.
The mistake during U7 rework
I checked the components around U7, removed and refitted parts, and continued trying to find out why it was not responding.
After one of those rework attempts, U7 became very hot as soon as I applied power. The ESP32 also became hot to the touch. I stopped powering the board, but removing U7 did not clear the fault. With power disconnected, I measured about 3 Ω between the 3.3 V rail and ground.
I eventually removed the ESP32 module for inspection. I later confirmed the assembly mistake: during rework, I had fitted U7 backwards. The chip’s unclear markings had contributed to my orientation mistake, and the incorrect installation damaged the ESP32.
The U7 area after the chip was removed. The red box marks the footprint; this is not a photo of the chip as it was installed when the fault occurred.
The board had already booted, connected to Wi-Fi, and read a voltage before this happened. The damaging mistake occurred during later rework.
The damaged ESP32-S3 module after removal from the board.
What I’m taking into the next attempt
The change I want to make to my process is specific: after removing and refitting a chip, check its orientation again before applying power. If the marking is hard to read, that needs resolving before soldering it back in.
I also want to keep better records of each rework step. With U6, I have the final voltage reading, but my notes do not identify the exact repair that restored it. Recording what changed between checks would make the next fault easier to follow.
The ESP32 has been removed, but the extent of the remaining damage still needs checking before I fit a replacement and resume testing.
TDS measurements, pump and valve operation, Home Assistant integration, and testing in the purifier are still ahead. The next job is to get this board back to a condition where I can continue those checks.
Update, October 28, 2026: The controller is now assembled and running in the purifier. Read the first machine test and flush-valve firmware fix.



Comments
Questions about this build? Share what you tried and what happened.
Loading the discussion…
Comments could not load. You can keep reading and try again.
New comments are closed for this article. Existing discussions are still available to read.
Your submitted comments
Shown only to you. Not part of the public discussion yet.
Discussion
No comments yet. Questions and build notes are welcome.
Replying to
Replying to